Reserve battery 12V200AH AGM Tubular battery
Basic Info
Model No.: LFP12200
Product Description
Automotive and traction applications.
Standby/Back-up/Emergency power for electrical installations.
Submarines
UPS (Uninterruptible Power Supplies)
Lighting
High current drain applications.
Sealed battery types available for use in portable equipment.
International certifications:
ISO9001 approval, FN: Q3105105131
ISO14001 CTC04912E10302ROM
OHS MS18001 04912S10150ROM
UL approval, FN:MH28204
CE approval, FN:G2M20201-0102-E-16
KS approval, FN:KS C 8519
VDS approval
BS approval
General Features
Nonspillable
Sealed and Maintenance-free Operation
High Quality and High Reliability
Exceptional Deep Discharge Recovery
Low Self-discharge
Long Service Life
Solid Copper Terminals
Tank-formed Plates
Computer-aided Design and Manufacturing
Typical Applications
Telecommunication equipment
Electronic instruments
Fire alarm
Security devices
UPS power supply
Emergency lighting
Specifications 1" cellpadding="0" cellspacing="0" style="width:514px;" class="tcs">
Absorbent glass mat technology; Nominal Voltage 12 V Capacity
(25ºC) 10HR(10.8V) 200 Ah 5HR(10.5V) 175Ah 1HR(9.60V) 124Ah Dimension Length 522±2mm (20.55inch) Width 238±2mm (9.37inch) Height 218±2mm (8.58inch) Total Height T5: 238±2mm (9.37inch) T11: 221±2mm (8.70inch) Approx. Weight 60.5kg (133.1lbs)±3% Terminal type T5/T11 Internal resistance
(Fully charged, 25ºC) Approx. 3mΩ Capacity affected by Temperature (10HR) 40ºC 102% 25ºC 100% 0ºC 85% -15ºC 65% Self-discharge
(25ºC) 3 month Remaining Capacity: 91% 6 month Remaining Capacity: 82% 12 month Remaining Capacity: 65% Nominal operating temperature 25ºC±3ºC(77ºF±5ºF) Operating temperature range Discharge -15ºC~50ºC(5ºF~122ºF) Charge -10ºC~50ºC(14ºF~122ºF) Storage -20ºC~50ºC(-4ºF~122ºF) Float charging voltage(25ºC) 13.50 to 13.80V
Temperature compensation:
-18mV/ºC Cyclic charging voltage(25ºC) 14.50 to 14.90V
Temperature compensation:
-30mV/ºC Maximum charging current 60A Terminal material Copper Maximum discharge current 1600A(5 sec.) Designed floating life(20ºC) 12 years
Recognized by UL & CE;
ABS container.
Dimensions
Terminal: T11(M8)
Constant Current Discharge Characteristics (A, 25ºC)
Constant Power Discharge Characteristics (Watt, 25ºC) F.V/TIME 10min 15min 30min 60min 2h 3h 4h 5h 6h 8h 10h 20h 9.60V 394 330 200 124 73.1 51.0 41.8 35.7 31.2 24.5 20.4 10.7 9.90V 382 322 196 122 72.6 50.7 41.6 35.5 31.0 24.3 20.3 10.7 10.2V 366 310 190 119 72.0 50.4 41.3 35.2 30.8 24.2 20.3 10.6 10.5V 350 300 185 117 70.9 50.0 41.0 35.0 30.6 24.0 20.1 10.6 10.8V 331 284 179 113 69.1 48.5 39.8 34.0 29.7 23.3 20.0 10.5
Note: The above characteristics data can be obtained within three charge/discharge cycles. F.V/TIME 10min 15min 30min 60min 2h 3h 4h 5h 6h 8h 10h 20h 9.60V 4253 3623 2244 1414 846 600 492 422 369 291 243 128 9.90V 4125 3536 2199 1392 841 596 489 419 367 289 243 128 10.2V 3955 3406 2132 1357 834 592 486 417 364 287 242 128 10.5V 3785 3290 2080 1330 821 588 482 414 362 285 240 127 10.8V 3573 3116 2004 1289 800 570 468 401 351 277 239 126
Product Categories : Network Power/Reserve Battery > Standard Series Battery